Product Details:
Payment & Shipping Terms:
|
| Genset Model: | SC1250E5 | Frequency: | 50Hz |
|---|---|---|---|
| Voltage: | 6300V/3 Phase | Type: | Open Type |
| Prime Output: | 1000KW/1250KVA | Engine Model: | Cummins KTA50-G3 |
| Alternator Model: | Stamford LVI 634G | ||
| Highlight: | industrial standby generator,industrial emergency generators |
||
3 Phase Industrial Diesel Generators 1000KW With 6300V High Voltage Marathon
| Generator set | Model No. | SC1250E5 |
| Standby power | 1375KVA/1100KW | |
| Rated power | 1250KVA/1000KW | |
| Output voltage | 6300V | |
| Rated speed (r/min.) | 1500 | |
| Noise level(7m) | 80dB | |
| Power factor | COSΦ=0.8 | |
| Phase/wires | 3 phase 4 wires | |
| Start mode | Electric | |
| Fuel consumption | 199L/h (average) | |
| Rated currency(amps) | 1800 | |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current. | |
| Engine | Brand | Cummins |
| Model | KTA50-G3 | |
| Original: | China | |
| Cylinders | 16 | |
| Fuel | 0# light diesel | |
| Inter-Cooling | water inter-cooling | |
| Compression Ratio: | 13.9:1 | |
|
Engine Power (prime/standby) |
1097KW/1227KW | |
| Aspiration | Turbocharged/Aftercooled | |
| Governor/Class | Electric | |
| Bore and stroke | 159×159 mm | |
| Start mode | DC24V electric start | |
| Cylinders Layout | V | |
| Displacement | 50L | |
| Alternator | Brand | Marathon |
| Model | MXH-1000-4 | |
| Protection | IP23 | |
| Frequency fluctuation | ≤±0.5 % | |
| Voltage distortion | <4% | |
| Power | 1288KVA(1030KW) | |
| Original | China | |
| Rated voltage | 6300 V | |
| Frequency regulation | ≤±0.5 %(stable) | |
| Voltage control | AVR |
| Technical parameters of Control Panel: | ||||
| Brand | Deep sea | Model | 6020 | |
| Function: | ||||
|
• Start or Stop Generator set manually / automatically • Open controller output can be defined as Pre-heat/Idle output • High Coolant temperature protection • Low Oil pressure protection • Over load protection • Generator over/under frequency protection • Generator over/under/unbalance voltage Protection • Over speed protection • AMF |
||||
| Note:Indicate this function depend on the set points of the controller in field. | ||||
| Optional accessories | |
| Engine | • Heater • Battery Charger |
| Alternator | • Permanent Magnet Generator(PMG) |
| Control system | • Remote Control Panel • Auto Transfer Switch (ATS) • Paralleling System |
| Fuel system | • Daily Fuel Tank • Water Separator • Fuel Level Sensor |
| Others | • Rainproof Type • Soundproof Type • Trailer Type • Extra spare Parts |
| Standard Accessories | Open type | Silent type |
| Sound-proof & Weather-proof Canopy | N/A | √ |
| Daily base fuel tank. 8 hours capacity | N/A | √ |
| Single-bearing generator again drops | √ | √ |
| Intelligent LED display control panel | √ | √ |
| Speed governor | √ | √ |
| Electric start and 12v charger | √ | √ |
| Standard air filter, oil filter, fuel filter | √ | √ |
| Cooling water tank | √ | √ |
| High-efficient silencer. | √ | √ |
| Exhaust elbow | √ | √ |
| Storage battery | √ | √ |
| Steel base-frame against vibration | √ | √ |
| Soft pipe for fuel and handle for lube going-out | √ | √ |
| Operation& Maintenance manual. | √ | √ |
| Drawing | Dimension |
|
Open type: 5200*1940*2520 mm |
|
|
Slient type: 6060*2440*2896 mm |
![]()
Remark:
Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(EQV ISO8528); a 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Contact Person: Henry Shawn
Tel: 86-13761066312