Send Message

Nanjing Stone Power Co.,Ltd

 

Power drive the world

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMarine Diesel Generator Set

High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm

I'm Online Chat Now
Certification
China Nanjing Stone Power CO.,LTD certification
China Nanjing Stone Power CO.,LTD certification
We are glad to get your goods about 500kva. the quality is good, our client is satisfy with it, it was really a good cooperation!

—— Pattawit

We are from spain, we visit this facotory and bought 2 gensets from them, we used for a several months, the quality is good, nice cooperation!

—— Rodrigo Calabrano

High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm

High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm
High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm

Large Image :  High Efficiency Marine Emergency Generator 710KW / 888KVA Pre - Low Oil Pressure Alarm Get Best Price

Product Details:
Place of Origin: CHINA
Brand Name: SUTONG
Certification: CCS
Model Number: CCFJ710J
Payment & Shipping Terms:
Minimum Order Quantity: 1 SET
Price: Negotiable
Packaging Details: Plastic package. LCL, 20FT , 40FT , 40HQ are available, according your order quantity
Delivery Time: 30
Supply Ability: 100 SET/month
Detailed Product Description
High Light:

marine emergency generator

,

portable marine generator

710KW / 888KVA CUMMINS MARINE GENSET HEAT EXCHANGER SEA WATER PUMP CCS

 

Cummins series marine main generator set and emergency set are provided, the power range from 20KW TO 1600KW, compact unit is easy to install, with low fuel consumption, good dynamic performance, high efficiency. The ship certificate of CCS, BV,NK or other major classification society can be provided.

 

 

Generator Set Model:

 

CCFJ710J

 

   

Performance of Generator Set:

 

400V,3phases,50Hz

Output:710kw/888kva

   

Prime Output Power:

 

710kw/888kva
   
   
   
   
   

Rating Conditions:

 

In accordance with ISO-3046 reference conditions:

 

-Air Pressure  100 Kpa

-Air Temperatur

 

45℃

 

-Relative Humidity  95%
- Power Deration   Operation at elevated temperature for sustained operation above 45℃ , derate by 2% per 11℃ .
   
   
Voltage 30VAC
Frequency  50Hz
Speed  1500 RPM
P.F.  0.8
Phase/Wire  3/3
   

Governor Type:

 

ELECTRIC TYPE

 

  10 %
  5 %

Recovery time

 

5 s

 

Frequency Variation Variation in Steady State

 

3%

Momentary Voltage Variation

 

-15%,+20%

Voltage Regulation in Steady State

 

2.5%

Voltage Variation in Steady State

 

3%

Recovery time

 

1.5 s
   

 

 

 

 

Engine Model:

 

KTA38-D(M)

 

- Prime Rating

 

746KW @ 1500 RPM
   

General Configuration:

 

 
  • No. of cycle

 

4
   

- Bore x stroke

 

159 mm x 159 mm
   
   

-Aspiration

 

Turbocharger , aftercooler

 

   

Performance data

 

 
   

General Data

 

 
   

Fuel System

 

 

-Maximum Allowed Restriction to Fuel Pump

 

20 Kpa

-Maximum Allowed Return Line Pressure

 

8 Kpa

-Fuel Consumption at rated power

 

209g/kw.hr (engine only)
   
   

 

Exhaust System

 

 

-Maximum Allowed Back Pressure

 

10 K Pa (3 in. Hg)

-Recommended New Engine Allowed Back Pressure

 

5 K Pa (1.5 in. Hg)
   

Air Induction System

 

 
-Maximum Allowed Intake Restriction  635 mm H2O
   

Lube Oil system

 

 

-Oil Pan Capacity, High/Low (Standard)

 

38/29.4Liters
   

-Maximum Operational Angularity of Oil Pan

 

 
Front Down  30°
Front Up  38°
Side to Side  38 °
   

Electrical System

 

24 V DC

 

Starting system

 

24VDC starting motor, 24VDC

Cold start temperature

 

0 ℃
   

Operation Fluids & Lubricants:

 

 

Fuel Oil

 

Diesel Oil is Grade No. 2-D requirements of the American Society for Testing and Materials (ASTM) ,Or China Fuel Type 0 – GB 252-8 (Grade 1 & Special Grade ) as equivalent, or China Fuel Type -10 – GB 252-87

( grade 1 & special grade ) as equivalent

   

Lube Oil

 

SAE 15W-40,

Grade CE, CF-4/SG, CG-4/SH or CH-4/SJ

   

Coolant

 

50-50 Ethylene Glycol/Water and Adequate

concentration of DCA4

  5

Main Alternator Model

 

 

Cummins WUXI Stamford LVM634E

 

LVM634E

 

Configuration of Main Alternator

 

 

 

Brushless

Single bearing 

Air cooling 

     

Technical Data of Main Alternator

 

   
- Capacity  KVA 1000
- p.f.   0.8
- Voltage   400VAC
- Frequency   50 Hz
- Insulation System    H
- Temperature rise    F
- Protection Class    IP23
- Phase/Wire    3/3
- POLES    4

 

 

 

 

 

 

 

 

 

 

 

   
Section C Supply Scope

 

 

MARINE GENERATING SET,CONSISTING OF ( PER UNIT)

 

 

G - DRIVE ENGINE, KTA38-D(M), WITH FOLLOWING EQUIPMENT:

 

 

1.1 AIR SYSTEM

  1. AIR CLEANER 
  2. TURBOCHARER
  3. AFTERCOOLER 

1.1.4 CRANKCASE VENT LINE 

 

1.2 COOLING SYSTEM 

1.2.1 FRESH WATER PUM,CENTRIFUGAL TAPY 

1.2.2 THERMOSTAT , FOR FRESH WATER 

1.2.3 WATER FILTER 

1.2.4 SEA WATER PUMP 

1.2.5 HEAT EXCHANGER 

 

1.3 LUB OIL SYSTEM

1.3.1 OIL PUMP 

1.3.2 OIL FILTER 

1.3.3 OIL COOLER 

1.3.4 OIL DIPSTICK 

1.3.5 OIL PAN 

 

1.4 FUEL OIL SYSTEM 

1.4.1 FUEL FILTER 

1.4.2 FUEL PUMP WITH ELECTRIC GOVERNOR 

1.4.4 FUEL/WATER SEPARATOR 

1.4.5 FUEL INLET/OUTLET FLEXIBLE SECTION

1.5 EXHAUST SYSTEM 

1.5.1 EXHAUST ELBOW 

1.5.2 EXHAUST FLEXIBLE SECTION AS LOOSE

1.5.3 SPARKLESS MUFFLER AS LOOSE 

1.5.4 FLANGE AS LOOSE 

 

1.6 STARTING SYSTEM 

1.6.2 24VDC START MOTOR 

1.6.3 MOUNTED ALTERNATOR 

2. ALTERNATOR LVM634E, LVM634E

2.1 AVR 

2.2 SPACE HEATER  , 220VAC

2.3 ONE POTENTIALMETER FOR VOLTAGE ADJUST AS LOOSE

 

  1. CABLE GLAND 

 

LOCAL CONTROL PANEL

3.1 OIL PRESS GAUGE 

3.2 WATER TEMP. GAUGE 

3.3 HOURMETER 

3.4 FREQUENCY METER 

3.5 POWER VOLTAGE 

3.6 START/STOP SWITCH 

3.7 EMERGNECY STOP BUTTON 

3.8 TEST/RESET SWITCH 

3.9 MONITORING SYSTEM: 

MONITORING SYSTEM FOR

  • RUN
  • PRE-LOW OIL PRESSURE ALARM
  • PRE-HIGH WATER TEMPERATURE ALARM
  • OVERSPEED SHUTDOWN 
  • LOW OIL PRESSURE SHUTDOWN 
  • HIGH COOLANT TEMPREATURE 

 

4. GENSET CONSTRUCTION: 

- STRONG COMMON BASEKID 

- ENGINE AND ALTERNATOR FLEXIBLE MOUNTING WITH ISOLATORS

 

- BATTERIES 

 

5.

QULIFICATION CERTIFICATE AND TEST REPORT

 

 

6. DRAWINGS AND DOCUMENT 

 

6.1) 2 copies of the followings approval drawings & documents should be submitted within 4 weeks after signing the contract   

  1. Installation Drawings 
  2. System Diagram 
  3. Electrical drawings (includes customer interface) 
  4. Technical sheet 
  5. Outline drawing of loose supply accessory

6.2) 2 copies of working drawing &document should be submitted with 14 working days after received confirmation,( The approval drawing will be confirmed as working drawing if not received confirmation within 2 weeks ) 

 

6.3) One copy per genset of final document should be submitted while genset delivered 

  1. Specialist tools list, 
  2. Parts catalog 
  3. Operation and maintenance manual 
  4. Engine test report 
  5. Name plate&Control panel in English

 

7. ONE SET OF CUMMINS STANDARD TOOLS PER ENGINE, MADE IN CHINA

 

 

Contact Details
Nanjing Stone Power CO.,LTD

Contact Person: Henry Shawn

Tel: 86-13761066312

Send your inquiry directly to us